{"product_id":"liquid-nitrogen-pumping-unit","title":"Liquid Nitrogen Pumping Unit","description":"\u003ch3 data-start=\"190\" data-end=\"217\"\u003e\u003cstrong data-start=\"194\" data-end=\"217\"\u003eGeneral Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"218\" data-end=\"263\"\u003eThe liquid nitrogen pumping unit consists of:\u003c\/p\u003e\n\u003cul data-start=\"264\" data-end=\"424\"\u003e\n\u003cli data-start=\"264\" data-end=\"307\"\u003e\n\u003cp data-start=\"266\" data-end=\"307\"\u003ea \u003cstrong data-start=\"268\" data-end=\"307\"\u003e180K quintuple liquid nitrogen pump\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"308\" data-end=\"365\"\u003e\n\u003cp data-start=\"310\" data-end=\"365\"\u003eall \u003cstrong data-start=\"314\" data-end=\"365\"\u003einstruments and controls mounted on the trailer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"366\" data-end=\"424\"\u003e\n\u003cp data-start=\"368\" data-end=\"424\"\u003ea \u003cstrong data-start=\"370\" data-end=\"399\"\u003e2,000-gallon working tank\u003c\/strong\u003e to ensure safe operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"426\" data-end=\"468\"\u003eThe liquid nitrogen unit is equipped with:\u003c\/p\u003e\n\u003cul data-start=\"469\" data-end=\"823\"\u003e\n\u003cli data-start=\"469\" data-end=\"551\"\u003e\n\u003cp data-start=\"471\" data-end=\"551\"\u003e\u003cstrong data-start=\"471\" data-end=\"524\"\u003eelectronic, manual, and remote-control interfaces\u003c\/strong\u003e for emergency situations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"552\" data-end=\"656\"\u003e\n\u003cp data-start=\"554\" data-end=\"656\"\u003ea \u003cstrong data-start=\"556\" data-end=\"578\"\u003eSiemens PLC system\u003c\/strong\u003e providing accurate operational data and safety control of the nitrogen pump\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"657\" data-end=\"823\"\u003e\n\u003cp data-start=\"659\" data-end=\"694\"\u003e\u003cstrong data-start=\"659\" data-end=\"682\"\u003eSiemens PLC screens\u003c\/strong\u003e displaying:\u003c\/p\u003e\n\u003cul data-start=\"697\" data-end=\"823\"\u003e\n\u003cli data-start=\"697\" data-end=\"747\"\u003e\n\u003cp data-start=\"699\" data-end=\"747\"\u003eoperating data and curves of the nitrogen pump\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"750\" data-end=\"823\"\u003e\n\u003cp data-start=\"752\" data-end=\"823\"\u003esimultaneous data on the screens of the \u003cstrong data-start=\"792\" data-end=\"823\"\u003ecoiled tubing control cabin\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"825\" data-end=\"828\"\u003e\n\u003ch3 data-start=\"830\" data-end=\"862\"\u003e\u003cstrong data-start=\"834\" data-end=\"862\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"864\" data-end=\"1313\"\u003e\n\u003cli data-start=\"864\" data-end=\"945\"\u003e\n\u003cp data-start=\"866\" data-end=\"945\"\u003e\u003cstrong data-start=\"866\" data-end=\"881\"\u003eDimensions:\u003c\/strong\u003e\u003cbr data-start=\"881\" data-end=\"884\"\u003eLength: \u003cstrong data-start=\"894\" data-end=\"902\"\u003e15 m\u003c\/strong\u003e\u003cbr data-start=\"902\" data-end=\"905\"\u003eWidth: \u003cstrong data-start=\"914\" data-end=\"923\"\u003e2.6 m\u003c\/strong\u003e\u003cbr data-start=\"923\" data-end=\"926\"\u003eHeight: \u003cstrong data-start=\"936\" data-end=\"945\"\u003e3.9 m\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"947\" data-end=\"976\"\u003e\n\u003cp data-start=\"949\" data-end=\"976\"\u003e\u003cstrong data-start=\"949\" data-end=\"960\"\u003eWeight:\u003c\/strong\u003e\u003cbr data-start=\"960\" data-end=\"963\"\u003e\u003cstrong data-start=\"965\" data-end=\"976\"\u003e26 tons\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"978\" data-end=\"1038\"\u003e\n\u003cp data-start=\"980\" data-end=\"1038\"\u003e\u003cstrong data-start=\"980\" data-end=\"995\"\u003ePower Pack:\u003c\/strong\u003e\u003cbr data-start=\"995\" data-end=\"998\"\u003e\u003cstrong data-start=\"1000\" data-end=\"1011\"\u003eCAT C15\u003c\/strong\u003e\u003cbr data-start=\"1011\" data-end=\"1014\"\u003e\u003cstrong data-start=\"1016\" data-end=\"1038\"\u003e595 hp @ 2,100 RPM\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1040\" data-end=\"1090\"\u003e\n\u003cp data-start=\"1042\" data-end=\"1090\"\u003e\u003cstrong data-start=\"1042\" data-end=\"1071\"\u003eMaximum Working Pressure:\u003c\/strong\u003e\u003cbr data-start=\"1071\" data-end=\"1074\"\u003e\u003cstrong data-start=\"1076\" data-end=\"1090\"\u003e15,000 psi\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1092\" data-end=\"1152\"\u003e\n\u003cp data-start=\"1094\" data-end=\"1152\"\u003e\u003cstrong data-start=\"1094\" data-end=\"1111\"\u003eDisplacement:\u003c\/strong\u003e\u003cbr data-start=\"1111\" data-end=\"1114\"\u003e\u003cstrong data-start=\"1116\" data-end=\"1141\"\u003e21,000 – 180,000 scfh\u003c\/strong\u003e (ft³\/hour)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1154\" data-end=\"1204\"\u003e\n\u003cp data-start=\"1156\" data-end=\"1204\"\u003e\u003cstrong data-start=\"1156\" data-end=\"1166\"\u003ePumps:\u003c\/strong\u003e\u003cbr data-start=\"1166\" data-end=\"1169\"\u003e\u003cstrong data-start=\"1171\" data-end=\"1204\"\u003eCS\u0026amp;P 1.25\" plunger, quintuple\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1206\" data-end=\"1259\"\u003e\n\u003cp data-start=\"1208\" data-end=\"1259\"\u003e\u003cstrong data-start=\"1208\" data-end=\"1234\"\u003eWorking Tank Capacity:\u003c\/strong\u003e\u003cbr data-start=\"1234\" data-end=\"1237\"\u003e\u003cstrong data-start=\"1239\" data-end=\"1259\"\u003e2,000 US gallons\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1261\" data-end=\"1313\"\u003e\n\u003cp data-start=\"1263\" data-end=\"1313\"\u003e\u003cstrong data-start=\"1263\" data-end=\"1291\"\u003eHigh-Pressure Manifolds:\u003c\/strong\u003e\u003cbr data-start=\"1291\" data-end=\"1294\"\u003e\u003cstrong data-start=\"1296\" data-end=\"1313\"\u003eSPM Fig. 1502\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GOES GmbH","offers":[{"title":"Default Title","offer_id":52492375195914,"sku":null,"price":350000.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0870\/8889\/0122\/files\/VorlageShopifyProduktbilder_1.png?v=1770022015","url":"https:\/\/europeanenerplus.com\/fr\/products\/liquid-nitrogen-pumping-unit","provider":"European EnerPlus ","version":"1.0","type":"link"}